04 Model 4  ·  AP-X03

Extreme Wind


For sites where exposure decides the engineering: coastal and waterfront developments, rooftops and elevated ground. One panoramic court, built to the site at two levels, with steel at the four corners only and 12 mm glass throughout.

Illustrative concept of the AP-X03-130 Extreme Wind court: a panoramic court with steel posts at the four corners only and the glass clamped along its full top and bottom edges.
AP-X03-130 · clamped glass edges — Illustrative concept
Illustrative concept of the AP-X03-150 Extreme Wind court: a panoramic court with steel posts at the four corners only and a glass fin behind every seam.
AP-X03-150 · glass fins at every seam — Illustrative concept
130 · 150 mph
Design targets, open site
12 mm
Tempered glass, SGCC
4
Corner posts only

Specification

Two models, one court


Both models are panoramic: steel posts at the four corners only, and no steel at any glass seam. What differs is how the glass carries the wind.

ModelsAP-X03-130: glass clamped along its full top and bottom edges (Wind Zone 3). AP-X03-150: a glass fin behind every seam (Wind Zone 4).
StructurePanoramic: steel posts at the four corners only, no steel at any glass seam; heavier head rail and corner posts than AP-P02 HW
Glass12 mm tempered, SGCC certified to ANSI Z97.1 / CPSC 16 CFR 1201
Wind design target130 mph (AP-X03-130) or 150 mph (AP-X03-150) on an open site, about 160 or 185 mph sheltered (ASCE 7-22), for engineering review
FinishHot-dip galvanizing (ISO 1461); the factory C5-M system and 316 stainless fasteners on AP-X03-150
Foundation6″ slab with perimeter ring beam and enlarged corner footings, sized by the engineer
Lighting8 × 300 W, 8 m poles
Playing area65'-7" × 32'-10" / 20 × 10 m

Built to order

Factory drawings, price and lead time are prepared for each project, and every site is confirmed by a US engineer’s stamped calculation. Design targets are for engineering review. Specification confirmed with each project.

Foundation

Sized against the site


AP-X03 uses Option B with an enlarged footing at each corner post: 6'-0" × 6'-0" × 2'-6" for AP-X03-130, about 7'-0" × 7'-0" × 3'-0" for AP-X03-150, with upgraded anchors. Issued as a project-specific detail — contact us before the slab is designed.

Groundworks guideline

The standard 6" slab and perimeter ring beam, with the corner footings enlarged per project and sized by the engineer.

Wind figures are design targets to ASCE 7-22 on an open site (Exposure C); a site sheltered by buildings or trees (Exposure B) is about 20% higher. AP-P02 suits sheltered sites and lower-wind areas; open sites across most of the inland US call for AP-P02 HW, and the Gulf and Atlantic coasts call for AP-X03. These are targets for engineering review, confirmed for each site by a US engineer’s stamped calculation before a site-specific quote.

The rest of the range

The rest of the range


3D view of the AP-I01 Super Panoramic Indoor court: glass-to-glass corners with no corner columns.

AP-I01

Super Panoramic Indoor

Minimal steel in the sightline. 42-unit suspended lighting ring at 7 m. Level slab, no ring beam.

AP-I01 in detail

3D view of the AP-P02 Panoramic Outdoor court: steel corner columns carrying the perimeter ring.

AP-P02

Panoramic Outdoor

The standard outdoor court, corner posts, 8 m pole lighting. Designed to a 90 mph target.

AP-P02 in detail

3D view of the AP-P02 Panoramic Outdoor court, shown for AP-P02 HW: the same open layout with corner posts only and no steel at the glass joints.

AP-P02 HW

Panoramic High Wind

The same open court with heavier corner posts and head rail. Designed to a 110 mph target.

AP-P02 HW in detail

All five side by side — the range at a glance

Five courts. One standard.

Tell us where the court is going.


Exposure, elevation and distance from salt air all change the engineering. Send us the site and we will tell you whether this is the model it needs.

Technical & drawing review

info@altapadel.us

Court Range Program

Sales & projects

sales@altapadel.us

Ready to start

Get started

Project intake form